When I check the water temperature on my Aqualink Control Center by quickly pressing the Pool Temp Boost button, it shows 85 degrees which I believe is correct. Do Not Sell or Share My Personal Information. The Jandy AquaPure, PureLink & Nature Fusion Soft Workbook gives a lot of good information on installation and troubleshooting. An optional pool pump timer can be utilized to help control this function. Cell trisensor senses temperature, salinity and flow. Please use a different way to share. Please note: This item is only available for in-store pickup and the selected store is out of stock. Remove cell for inspection. Find many great new & used options and get the best deals for E1 Jandy PLC1400 AquaPure 3-Port Salt Water Pool System at the best online prices at eBay! For a better experience, please enable JavaScript in your browser before proceeding. A letter will be included with each new Tri-Sensor ALERTING Installers about the new installation instructions. AquaPure Guide d'installation et mode d'emploi. See Section 6 of the owner's manual, User Maintenance Instructions. The cartridge must be replaced. The TRI sensor only pertains to the swg. This site is protected by reCAPTCHA and the Google. Told me from the serial number on unit it should have been included. Recheck. Check that unit is correctly wired for 240 VAC and connected to 240 VAC. While the salt shouldn't have any effect on the person if a small amount is swallowed, please keep in mind that the water is chlorinated and chlorine should not be consumed. When a FREEZE CONTROLLER is used on pump equipment and the chlorinator is run through the winter, turn the CHLORINE PRODUCTION down to 10 - 20%. Installation by a qualified pool professional required. Jandy APUREM AquaPure Salt Generator Power Center, Brand new returned unit - Never installed just opened, Create a Saltwater Oasis in Your Backyard, Automatic self-cleaning feature ensures consistent operation and extended lifespan of the cell, Exclusive Tri-Sensor technology provides reliable electronic water flow detection to sustain maximum performance, even at very low flow rates, Digital salinity read-out for accurate salt-level indication, Flow, temperature and status readings provide instant feedback on the current operation, When combined with PureLink power centers, AquaLink and AquaPure work together for the ultimate in pool sanitizing and remote operation convenience, Seamless communication with AquaLink Control systems enables easy monitoring of salt levels and convenient, precise sanitizer output settings, Note: The salt cells are sold separately
Using genuine Jandy factory replacement parts helps to ensure the ongoing quality and reliability of our products. Sign up for regular updates and to get the Jandy Drop-In Replacement Guide for model comparisons, dimensions, and more. The AquaPure system offers two cells that can generate different maximum amounts of chlorine in a 24 hour period. See Section 2, Figures 2a, 2b, and 2c of the owner's manual. Turn the chlorinator off or reduce the chlorine production percentage to zero. Drop in the Best When You Replace the Rest. Turn power to unit off and back on (Cycle Power). It is being practiced by thousands of pool owners just like you. Product information Feedback Would you like to tell us about a lower price? The Sensor Interface Module is weatherproof and should be left outside (Fig 3a) of the power center enclosure (Fig 3b). We made the decision to go to a salt water pool system. Sign up for regular updates and to get the Jandy Drop-In Replacement Guide for model comparisons, dimensions, and more. Being relatively adept, I chose to install this myself. Determine the amount of salt necessary to add from an appropriate chart. Would recommend it to anyone needing a replacement or installinf for the first time. Shop Online or at any of our 900+ retail stores! Reviewed in the United States on April 8, 2017. (Use sodium chloride only). Increase the system operating time per day. Rather than swapping my existing power center for 6613-AP (no breakers), I prefer to add an APUREM subpanel power center and run the four-wire harness over to the iAquaLink board. Please try again. It should read 75 F or 24 C. Next, press and hold the board H-Temp test button, and at the same time press the Salinity key (C) together with the Chlorine Production Rate arrow down key (A) on the front cover of the unit. No, a pool treated by salt water chlorination is a chlorinated pool in which the chlorine is produced automatically. Using genuine Jandy factory replacement parts helps to ensure the ongoing quality and reliability of our products. You can buy this product once, or subscribe to have this product delivered to you as frequently as you wish. Rely on its sturdy design and simple features to create your saltwater oasis. Salt level may decrease after a heavy rain, backwashing, refilling, draining or excessive splash out. Please select a nearby store with available inventory to process your order. Jandy Aquapure Control Center. Boost 24 Hour 100% Chlorine Production Cycle. We are sorry. High salt concentration above 4.0 gpl may damage the power center. Perks can be redeemed online, in store or in the Leslies app. (567 gm/24 Hr.). Please try again later. I have upgraded the circuits boards as per Zodiac's support advice and they only made the problem less prevalent. Manufacturer SKU: 6967+. As for information, the internet is a great thing. All other forms of chlorine (tablets, powder, liquid, etc.) Rely on its sturdy design and simple features to create your saltwater oasis. Told me from the serial Recieved and installed myself. The controller will periodically change the direction of the cell current in order to eliminate the layers of scale that deposit on the electrode plates. The remaining bromide in the pool will produce a white emulsion (chemical reaction). You have 3 temp sensors. Quantity. Find inspiration for your home and garden. See Section 6.3 of the owner's manual Electrolytic Cell Cleaning. However there is a jumper on the Power Interface Board that is connected for the 1400 cell and cut for the 700 cell. If the Aquapure is disconnected from the Aqualink, then you should be able to set chlorine production from the front panel on the Aquapure. Pool guy installed quickly and it is working great. Find many great new & used options and get the best deals for Jandy Aquapure Clormatic III Front Panel Control Board Psd306-01 Apure1400 at the best online prices at eBay! The water balance will be less threatened, because only pure chlorine is added to the water. The AquaPure system is comprised of the following three component parts and an optional pool pump timer. A 121 error can occur for a number of different reasons: dirty cell, damaged cell, bad cell cable, low salt level, cell wearing out due to age, or damaged power supply. Ensure that the flow/temp/salinity sensor is installed according to Section 3, Figure 11 of the owner's manual. It measures temperature, salinity and flow. 99. Reviewed in the United States on June 20, 2014. If corrosion appears in one year, it can be explained by incorrect water chemistry or bonding issue, not by the presence of salt alone. Filter, Hayward Star-Clear Cartridges C-250 thru C-1750, Hayward Swim Clear Large Capacity Cartridges, Pentair Purex Bottom Manifold Filter Grids, Pentair Replacement Cartridges QUAD Filters, Filter Backwash Valves, Diverter Valves, Check Valves, Hayward Navigator - PoolVac Cleaner Parts, Pool Control Systems and Automation Parts, Aquarite Cell Replacements - Above Ground, Hayward Aquarite Goldline Parts, Sensors, Boards, Jandy Zodiac Salt Cell PLC1400 Aquapure1400 PureLink Cell Kit 40K, Jandy PLC700 PureLink 7-Blade Salt Generator Cell Kit, Hayward Salt & Swim 3C Control Unit Only W3SAS-PRO, Hayward Salt & Swim 3C Replacement Salt Cell W3SAS-CELL, Pentair IntelliChlor Salt Generator Above Ground Pools IC15 EC-520888, SmartSalt Salt Chlorine Generator 25K 25,000 Gallons, Hayward AquaTrol RJ Salt Chlorine Generator W3AQ-TROL-RJ, Pentair Intellichlor IC60 Salt Water System 521105 and 520556. Plug flow/temp/salinity sensor into connector on power center printed circuit board. Q: Recieved and installed myself. If its 02110A10 or 01220A15, you use program A, otherwise you use program B on the in-line module on the trisensor cord. PLC1400 (Cell Kit), Dolphin Above Ground Robotic Pool Cleaners, Dolphin Residential Robotic Pool Cleaners, Solar Cover Blankets - Above Ground Pools, Utility Company Rebates for Pool Equipment, Kreepy Krauly Pool Cleaners Above Ground Pools, Kreepy Krauly Pool Cleaners Inground Ground Pools, Polaris Pool Cleaners - Above Ground Pools, Pentair Above Ground Pool and Spa Pool Heaters, Pentair Master Temp Inground Pool and Spa Heaters, Raypak Pool and Spa Heaters Gas and Propane, Hayward Commercial Thermoplastic Pump HCP Series, Hayward DEP 500 Series Pleated Element D.E. Can I switch from bromide to salt water chlorination using the same water? The aquapure power center is an electrical panel that is installed at the equipment pad. It is the box in which the bezel, printed circuit board, service control panel and relays of the system control are installed and to which the pool equipment is connected. Note: Pool Pump and Control Center to AquaPure Must be Wired to Turn On and Off Together AquaPure Control Center 115/230VAC Electrical Supply Return to Pool From Pool Cell Pump Flow / Salinity Sensor Filter Heater To Drain (Backwash) Salt for Pool A q u a P u r e Options List 1. 96. New, not old stock, in sealed box. I bought one of these units from another vendor three years ago. Find a Dealer AquaPure Salt Water Pool System Downloads Document ID SL6605 Many of these units have been shipped with bad circuit boards, as my pool professional was told by the Jandy tech. Add salt as described in Section 4.7 of the owner's manual. It includes aquapure control box only. Get 1 point for every $1 spent. Check connection. Register product at Jandy.com/registration. If the readings are correct then the board is O.K. You can check the calibration by doing the following below procedure. The Jandy AquaPure APUREM salt-water chlorine sanitizing systems use salt water to deliver high-performance water sanitation with uncompromised performance, reliability and hydraulic efficiency. See Section 5 of the owner's manual, Operating Instructions. Hypochlorite kills bacteria, oxidizes organic material, and kills algae then reverts back to salt. Jandy has the Jandy SP3P Dummy Cell Cleaning Kit that includes everything you need to remove, clean, store, and/or bypass your Jandy AquaPure 3-Port Salt Cell. If not, contact a pool professional. The salt water chlorinator replaces the hassle of having to use granular chlorine. Add To Cart. The item you are trying to purchase is currently out of stock.Please enter your name, email, and phone number below. In addition, the AquaPure threads are proprietary and Jandy does not offer replacement proprietary unions (the "male" piece). The LCD display on the user interface offers monitoring of chlorine production, cell modes, salinity level, temperature, water flow and diagnostics. IS this the complete system? After installing began to flash code of 181 & 172. It has 1 year manufacturer warranty. Natural stone can be visually altered over time. (Cycle Power). See Section 4, Table 2 of the owner's manual. Polarity will change every 3 hours. Be the first to review this product! Sitemap | It's cheaper to go with another salt Unit came with panel knocked out and the circuit board was bad. Is it true that salt water chlorination is maintenance free? The cell cannot be repaired even though the plates may have life left in them. Jandy AquaPure 1400 Chlorine Generator Quick Specs View Detailed Specs Power: 1.25 lbs/day 90-Day / 1 Year Limited Warranty 8000 Hours Rated Lifespan 40000 Gallons Max Capacity Description Reviews Specs Controls Cell Warranty "The Heavy-Duty Standard for Maximum Performance" There were instructions included, but they were not as comprehensive as you would really need. See Section 5, Operating Instructions section of the owner's manual. We selected and analyzed the cases involving AEDs. Full content visible, double tap to read brief content. 3.9 out of 5 stars 35. From the Jandy controller, you can see the salt PPM, and you get a An excellent system. #1. Aqualink prevents the Aquapure system from proper operation without a functioning water temperature signal from the Aqualink stand alone water temperature sensor, regardless of what the SWG flow sensor says. Jandy Pro Series AquaPure Power Pack AquaPure Salt Chlorinator Models Sanitizer Type Body Material Chlorine Connections Input Current Output Pool Size Recommended Flow Rate Maximum Pressure Recommended Tablets Chamber Capacity of Chlorine AquaPure Power Pack and PureLink Cell Kit, 7 Blade #PLC700 Saltwater Chlorinator PPGF Looks like your current store isn't near your delivery area. Jandy no longer supports parts for their older systems. However, the Jandy PLC700 cell kit (for pools up to 12,000 gallons) and the PLC1400 (with a 40,000 gallon capacity) kit contain new cells as well as all the necessary accessories to switch a 2-port setup to the new design.[8]. If the cell is old, just get the PLC1400 kit. It appears that Aqualink stops talking to Aquapure when the Aqualink water temperature sensor is inoperative.[12]. Most cases of corrosion can be better explained by an incorrect water chemistry as opposed to the presence of salt. First thing to check is the cord. This Jandy Power Center Transformer is compatible for use with the AquaLink RS and AquaPure automatic control systems. Red goes to green and blue goes to black/white. Try (carefully) blowing a hair-dryer on the air temp sensor and see which temperature reading increases on your PDA. The Jandy tri-sensor measures water flow, salinity, and water temperature. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. Being relatively adept, I chose to install this myself. All other firmware uses program B on the trisensor inline module. iAqualink 2.0 is Wi-Fi for the Aqualink system. Otherwise the back circuit board may need replacement. We are a registered 501(c)3 non-profit that is funded by user donations. We could have gotten by with the PLC700 but this gave us a larger cell. Release the button after the 3rd beep. Zodiac Jandy iAquaLink 2.0 Wireless Network Pool Control Interface Sys. The PDA uses the pool's temperature sensor. $195.99. If still too low, Super Chlorinate with outside source. You need the Aquapure system with the control box and cell. Will there be any harm if someone swallows salt water in a salt chlorinated pool? There are beads at the bottom of my pool, what does it mean? See pages 13-14 in Jandy AquaPure Troubleshooting. The PLC1400 cell is Jandy P/N R0452400. If removing the cell is desired so that water may circulate without the cell, specialized plumbing would need to be added during installation of the cell. See Section 5.4 of the owner's manual, Startup. Make sure that the salt is very well mixed by brushing thoroughly at least 5 times. Check Cell studs for same. Andy tech support makes jokes that I should get it fixed before my pool turns green and yet have not been able to fix the problems nor willing to try. Is this unit a compatible replacement for an Aquapure 1400 control? 2023 Zodiac Pool Systems LLC - All rights reserved. It is usually located underneath your Aqualink cabinet. This difference in readings started about 1 week ago. A separate communication will follow . Must be picked up in our Moorpark, Ca location to qualify for the Jandy limited warranty. | IQ20-A. Buy in monthly payments with Affirm on orders over $50. The LCD should read 2.8 gpl*. The PureLink Power Centers combine all the features of the AquaLink Power Centers and AquaPure water purification electronics in one box. 1 - Mounting Bracket, User Interface, APUREM. The Jandy AquaPure system consists of a AquaPure Power Center or PureLink Power Centers and either a PURE700 cell or a PURE1400 cell. Will salt from the salt water chlorinator deteriorate the metal components in my pool?
contain additives. Fits Zodiac Jandy AquaPure PureLink cell kit, It is a weather resistant metal case and 4 relays, Measures 6-inch diameter by 14-inch width by 9-1/2-inch height; 1 year manufacturer warranty, Home & garden magazines included in Kindle Unlimited. Refer to Maintenance Procedure for acid wash cleaning. Check that ribbon cable is fully inserted into connector. Jandy switched to a 3-port cell design to aid in cleaning and plumbing flexibility and no longer makes 2-port cells. 21. If the actual salinity is above 4.0 gpl (4,000 ppm), the pool needs to be diluted to get the level below 4.0 gpl. The AquaPure salt-water chlorine sanitizing systems uses salt water to deliver water sanitation by generating chlorine. Jandy makes the Purelink Power Center that combines the Aqualink and Aquapure controls in one cabinet. Disconnect the flow salinity temp sensor from the front board. Your question might be answered by sellers, manufacturers, or customers who bought this product. The manual says that the unit can be damaged, which could void the warranty. The Jandy AquaPure salt-water chlorine sanitizing systems use salt water to deliver high-performance water sanitation with uncompromised performance, reliability and hydraulic efficiency. eschewing the conventional role in traditional architectural hierarchies, this project acts as a catalyst to an overcrowded favela by bringing in social infrastructure and a connection between top . Drop in the Best When You Replace the Rest. Select your subscriptions from a range of popular titles. Andy tech support makes jokes that I should get it fixed before my pool turns green and yet have not been able to fix the problems nor willing to try. Can this be used to replace an old Aquapure 1400 control box? I bought one of these units from another vendor three years ago. No instructions contained w/unit. I would say your pool temp sensor has gone bad. Recommend strongly. In the case of a salt water chlorinator, the salt may damage the stone along the water line over time (crystallization).